| Windmill Cables | |||
| EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable | HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable | Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ | more |
Windmill Cables
I-V2Y(ZN)11Y/I-V2Y(ZN)2Y POF Breakout Cable
Application
I-V2Y(ZN)11Y/I-V2Y(ZN)2Y POF Breakout Cables are used in mechanical engineering, both in mobile and
fixed applications, suitable for applications where trouble-free data transmission in necessary under heavyduty
conditions.
Standards
DIN VDE 0888
IEC 60794
Construction

Fibre Type: POF 980/1000.
Strain Relief: Aramid yarns.
Break-out Unit Sheath: PE.
Outer Sheath: PE/PUR.
Optional Element: Copper element or dummy element.
Technical Data
Operating Temperatures:-20℃~+80℃
Minimum Bending Radius:30~95mm depend on cable construction
Oil Resistant:Yes
Dimensions and Weight
| Construction | Copper Element | Core/Cladding Diameter |
Nominal Overall Diameter |
Nominal Weight |
|---|---|---|---|---|
| No. of POF element | No. of cores×mm² | μm | mm | kg/km |
| 1 | - | 980/1000 | 5.8 | 30 |
| 2 | - | 980/1000 | 6.0 | 36 |
| 4 | - | 980/1000 | 7.1 | 65 |
| 2 | 2×1 | 980/1000 | 7.8 | 60 |
| 2 | 3×1.5 | 980/1000 | 11.0 | 132 |
| 4 | 19×1 | 980/1000 | 16.0 | 440 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information